Cantilever Stacker
This system is installed to park only one car on the platform and the ground level is left clear for vehicular movements. The system has column arrangement only on one side, generally on the boundary side, leaving the entire driveway clear for passage.
TYPE | Single Column Cantilever Stacker |
---|---|
MODELS | E2CS/E2CM/E2CB |
NO. OF CAR PER UNIT | 1 Car |
LIFTING CAPACITY | 2000 Kg [ Car Weight] |
LIFTING TIME | 2 m/min |
OPERATION | Hydraulic Power Pack, One Cylinder with Key/Push button operation. |
POWER SUPPLY | 415 V, 3 phase, 50 Hz |
POWER CONSUMPTION | Up to 0.03 units per operation (approx.) |
Specification Table
Standard Features
Requirements from Client
Specification Table
MODEL | SYSTEM | PLATFORM | PLATFORM | LOWER CAR | LIFTING | CAR |
E2CS | 2300 | 1900 | 4000 | 2200 | Hydraulic | Small Cars |
E2CM | 2500 | 2100 | 4500 | 2200 | Hydraulic | Mid Sized Sedans |
E2CB | 2800 | 2300 | 4500 | 2200 | Hydraulic | Large Sedans / SUV’s |
Standard Features
- Vehicles can be driven across stacks.
- One Platform per system.
- Lifting mechanism installed only on one side of the Stack.
- Color scheme for the System will be provided as per the clientÔÇÖs color theme.
- Hot dipped Galvanized Corrugated floor plates to reduce dead weight and increase durability.
- Compact Power pack system with enclosed motors and rubber bush fittings for reduced noise levels.
- Optional Photo sensor for the bottom car to prevent accidental lowering of upper stack.
- Electromagnetic locking mechanism to prevent unwanted lowering of upper stack.
- Limit switches to restrict the travel height by auto cutting off the motor.
- Remote switch box with Key/Push button for easy operation.
- Emergency Shutdown switch
Requirements from Client
- Parking area allotted must be cleared with no obstructions.
- Additional space to be provided for storing and installing the Power Pack system.
- While erection of the system client should provide storage facilities for keeping our tools and other valuable parts of the system.
- Temporary Electrical connection must be provided at the time of erection and installation of the systems.
- 12 Amps MCB and Main Electrical Connection (or 4 Pole RCBO) along with electrical cable fitting must be provided from the Main Power supply to the parking systems with 3Ph 415V AC, 50Hz with Neutral and Earth (3Ph+N+E).
- Incoming Cable Size should be at least 4 Core x 2.5 sq.mm. Flexible Copper multi Core cable (3PH+N+E) from Main Switch to Control Panel.
- Civil work as foundation for Cantilever parking system must be done at allotted area prior to installation as per our Foundation drawing.
- Foundation Concrete shall be of RCC and minimum M25 strength.
- In case of Parking Installed in open to Sky location, it is recommended to have a weather covering over the installation to prevent damage to the electronics / mechanism due to weathering.