This is Parking System offers parking for 3 cars; one on the ground and two on the two upper levels. The car on the ground level will need to be removed before lowering the first level platform; similarly the ground and first level cars will need to be removed before lowering the second level platform.

TYPE | Three Level above Ground Stacker |
---|---|
MODELS | E3SS/E3SM/E3SB |
NO. OF CAR PER UNIT | 3 Cars |
LIFTING CAPACITY | 2000 Kg [ Per Car Weight] |
LIFTING TIME | 2 m/min each stack |
OPERATION | Hydraulic Power Pack, One/Two Cylinder with Key/Push button operation. |
POWER SUPPLY | 415 V, 3 phase, 50 Hz |
POWER CONSUMPTION | Up to 0.04 units per stack operation (approx). |
MODEL | SYSTEM | PLATFORM | PLATFORM | LOWER CAR | LIFTING | CAR |
E3SS | 2300 X 4500 | Level 2 – 1700 | Level 2 – 3700 | ALL LEVEL | Hydraulic / | Small Cars |
E3SM | 2500 X 5500 | Level 2 – 1900 | Level 2 – 4000 | ALL LEVEL | Hydraulic / | Small Cars/ |
E3SB | 2700 x 5500 | Level 2 – 2000 | Level 2 – 4000 | ALL LEVEL | Hydraulic / | Mid Sized Sedan/ |
- Fast and automatic retrieval of cars from the parking Space without removing any cars parked on the ground level of the system.
- One Slot left empty at each level to make way for the upper platform to pass through.
- Hot dipped Galvanized Corrugated floor plates to reduce dead weight and increase durability.
- Geared motor with minimum Safety factor of 2 with manual brake release.
- Motor- Chain operated Sliding Mechanism.
- Single Power Pack per system to reduce cost in case of hydraulic puzzle
- Complete system monitored by PLC for smooth and error free automation.
- Back up Limit switches provided for each slot for duplex safety.
- Fabricated barriers provided on each platform to provide safety against unwanted lowering.
- Fully automatic integrated operation.
- Emergency Shut Down switch.
- Optional Touch Screen/Numerical Keyboard operation Panel.
- Parking area allotted must be cleared with no obstructions.
- While erection of the system client should provide storage facilities for keeping our tools and other valuable parts of the system
- Temporary Electrical connection must be provided at the time of erection and installation of the systems.
- MCB and Main Electrical Connection (or 4 Pole RCBO) along with electrical cable fitting must be provided from the Main Power supply to the parking systems. With 3Ph 415V AC, 50Hz with Neutral and Earth(3Ph+N+E) as per our specifications.
- Civil work as foundation for parking system must be done at stack parking allotted area prior to installation as per the foundation plan submitted by us.
- Base area of the parking space allotted shall be Concrete with minimum strength of M20.
- In case of Parking Installed in open to Sky location, it is recommended to have a weather covering over the installation to prevent damage to the electronics / mechanism due to weathering.